This oxygen system is made of polar spectrometry and the film-making oxygen electrode (also known as a CLARK electrode). The molecular oxygen passes through the membrane from the liquid medium into the electrode electrode electrolyte, under a certain polarized voltage, oxygen is reduced, generating current. The oxygen in the film-making oxygenation electrode is in the neutral electrolyte:

Cathode O2 + 2H2O + 4C = 4OH

Anode 4AG + 4CL-4E = 4AGCL

The current is proportional to the concentration of oxygen, and the electrolytic current is enlarged, calculated, and oxygen concentrations are displayed by electronic units.

In the oxygen reduction process, the electrode consumes oxygen, and oxygen must be continuously supplied by the medium. Therefore, when using the instrument to measure the oxygen concentration, the medium must be constantly flowing to ensure the correct and reliable measurement.

(1) The role of the instrument function key:

  1. Correct the regulator:

Used to measure the oxygen and dissolved oxygen in the air in the air to adjust.

2, oxygen / dissolved oxygen switch:

This switch is used to measure the conversion of oxygen and dissolved oxygen in the gas. When the switch protrudes, the gas in the gas is measured; or the dissolved oxygen air scales can also be directly measured when the switch is pressed, and dissolved oxygen is measured.

3, range selection switch:

Range switch points left, medium and right. The measurement range of each file is determined according to customer requirements.

If you use portable micro-dissolved oxygen monitoring data

  1. After the instrument is turned on, the instrument is placed in% gear. When the oxygen electrode is placed in the air, after stabilizing (2-3) minutes, adjust the correction regulator, causing the instrument to display 20.6%. Instruments such as precision measurement, the corrected data should be highly and humidity corrections (see appendix).
  2. After the sample measurement – After the instrument correction, the oxygen electrode flow cell is loaded, and the sample will enter the flow cell, the sample hold flow rate is greater than 10 cm / sec. Press the aerobic / dissolved oxygen switch and placed in the MG / L file. After the instrument is stabilized (2 – 3) minutes, the recording reading (mg / L) is the dissolved oxygen of the sample.
  3. View more quality oxygen analyzers with low price and free shipping all over the world.

2 comments

  1. Right here is the right webpage for everyone who really wants to understand this topic.
    You know a whole lot its almost tough to argue with you (not that I personally
    would want to…HaHa). You definitely put a brand new spin on a topic that’s been written about for a long time.
    Excellent stuff, just great!

    Look into my web page vpn coupon 2024

  2. great publish, very informative. I wonder why
    the opposite experts of this sector don’t notice this.
    You must proceed your writing. I’m sure, you’ve a huge readers’ base already!

    Here is my webpage vpn special coupon code 2024

Leave a Reply

Your email address will not be published. Required fields are marked *

Free Worldwide shipping

On all orders above $50

Easy 30 days returns

30 days money back guarantee

International Warranty

Offered in the country of usage

100% Secure Checkout

PayPal / MasterCard / Visa